Soojuse ja elektri koostootmisjaamagriKomp GmbH
BGA/NGA168
Soojuse ja elektri koostootmisjaam
agriKomp GmbH
BGA/NGA168
tootmisaasta
2024
Seisund
Uus
Asukoht
Merkendorf 

Pildid näitavad
Kuva kaart
Andmed masina kohta
- Masina nimetus:
- Soojuse ja elektri koostootmisjaam
- Tootja:
- agriKomp GmbH
- Mudel:
- BGA/NGA168
- Tootmisaasta:
- 2024
- Seisund:
- uus
- Töövõimekus:
- täielikult töökorras
Hind ja asukoht
- Asukoht:
- Energiepark 2, 91732 Merkendorf, Deutschland

Helistada
Tehnilised andmed
- Võimsus:
- 350 kW (475,87 hj)
Pakkumise üksikasjad
- kuulutuse ID:
- A16761621
- Värskendus:
- viimati kuupäeval 09.09.2024
Kirjeldus
Compact, highly efficient combined heat and power unit with a state-of-the-art SCANIA V 8-cylinder, lean-burn gas turbo, 4-stroke gas Otto engine. Unit, gas pressure control system, mixture and engine water cooling circuit mounted on base frame for power and heat generation with a high-quality synchronous generator (3P, 400V, 50Hz) for mains/parallel operation and optimized heat extraction via plate heat exchanger for heating water/process heat with a temperature level of VL 85°C / RL 70°C,
OPTIONAL: with catalytic converter (optional SCR system) for low-emission operation in accordance with the MCP Directive (EU) and 44th BImSchV (DE).
Podpjt Uu Ezjfx Agnsrd
TECHNICAL DATA
GENSET /CHP - Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output motor at 180^exhaust gas temperature: 334 kWth
Electricity coefficient el/th. : 1,05
Engine type V8
Displacement: 16 Ltr
Combustion thermal output - 100% load: 845kWel
Gas consumption at50%CH4: 169.1Nm³/h
Length x width x height m 4.1 x 1.5 x 2.1
Weight unfilled 4500kg
The CHP has a control cabinet with a display for the visualization of all relevant operating parameters including a DSL modem for remote maintenance and external monitoring, as well as an interface for control energy for connection to the Energiepilot E2M. The scope of delivery includes a mains starter to provide the optimum starting speed, as well as a gas detector, smoke detector, emergency stop switch and alarm flashing light/horn.
All pipes are made of V2A and insulated where necessary.
To ensure that the motors are kept warm, the installed heat pumps are programmed to start up in a set cycle,
that they start up in a set cycle and thus enable the desired temperature to be maintained.
An automatic gas shut-off valve for installation outside the CHP installation room is not included in the scope of delivery.
The CHP unit complies with the medium-voltage directive VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP installation room and all operating fluids are not included in the scope of delivery.
The CHP unit is also optionally available in a container.
The entire unit is also available as a natural gas version.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
OPTIONAL: with catalytic converter (optional SCR system) for low-emission operation in accordance with the MCP Directive (EU) and 44th BImSchV (DE).
Podpjt Uu Ezjfx Agnsrd
TECHNICAL DATA
GENSET /CHP - Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output motor at 180^exhaust gas temperature: 334 kWth
Electricity coefficient el/th. : 1,05
Engine type V8
Displacement: 16 Ltr
Combustion thermal output - 100% load: 845kWel
Gas consumption at50%CH4: 169.1Nm³/h
Length x width x height m 4.1 x 1.5 x 2.1
Weight unfilled 4500kg
The CHP has a control cabinet with a display for the visualization of all relevant operating parameters including a DSL modem for remote maintenance and external monitoring, as well as an interface for control energy for connection to the Energiepilot E2M. The scope of delivery includes a mains starter to provide the optimum starting speed, as well as a gas detector, smoke detector, emergency stop switch and alarm flashing light/horn.
All pipes are made of V2A and insulated where necessary.
To ensure that the motors are kept warm, the installed heat pumps are programmed to start up in a set cycle,
that they start up in a set cycle and thus enable the desired temperature to be maintained.
An automatic gas shut-off valve for installation outside the CHP installation room is not included in the scope of delivery.
The CHP unit complies with the medium-voltage directive VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP installation room and all operating fluids are not included in the scope of delivery.
The CHP unit is also optionally available in a container.
The entire unit is also available as a natural gas version.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.