For sale is a Zwick/Roell Z2.5/TS1S material testing machine with a nominal force of 2.5 kN.
Technical data
Manufacturer: Zwick/Roell
Type: BZ2.5/TS1S
Year of manufacture: 2006
Nominal force: 2.5 kN
Max. working space height: 573 mm
Testing speed: 0.1 to 800 mm/min
Precise guidance and DC drive
Includes hardness testing device for optical methods (HV, HK, HB) according to the existing equipment
Ledpfx Adsz S D Skjcshn
Condition: The machine is currently not operational, as the installed load cell measures outside the permissible tolerance and the calibration failed. According to current knowledge, the cause lies in the area of the force measuring device.
The machine was operated until the deviation was detected. The drive, mechanics, and other components have not been further inspected and are therefore explicitly offered without any guarantee of functionality.
Scope of delivery
Zwick/Roell Z2.5/TS1S material testing machine
Existing accessories according to the photos
Documentation, if available
The machine is explicitly sold as defective and untested.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Technical data
Manufacturer: Zwick/Roell
Type: BZ2.5/TS1S
Year of manufacture: 2006
Nominal force: 2.5 kN
Max. working space height: 573 mm
Testing speed: 0.1 to 800 mm/min
Precise guidance and DC drive
Includes hardness testing device for optical methods (HV, HK, HB) according to the existing equipment
Ledpfx Adsz S D Skjcshn
Condition: The machine is currently not operational, as the installed load cell measures outside the permissible tolerance and the calibration failed. According to current knowledge, the cause lies in the area of the force measuring device.
The machine was operated until the deviation was detected. The drive, mechanics, and other components have not been further inspected and are therefore explicitly offered without any guarantee of functionality.
Scope of delivery
Zwick/Roell Z2.5/TS1S material testing machine
Existing accessories according to the photos
Documentation, if available
The machine is explicitly sold as defective and untested.