Weiss ShockEvent D/210/a/V1 veega jahutatav -65 kuni +200 °C, 210 liitritWeiss
Vötsch Schocktestkammer
Weiss ShockEvent D/210/a/V1 veega jahutatav -65 kuni +200 °C, 210 liitrit
Weiss
Vötsch Schocktestkammer
Seisund
Kasutatud
Asukoht
Borken 

Põhiandmed
Hind ja asukoht
- Asukoht:
- Borken, Saksamaa

Helistada
Pakkumise üksikasjad
- kuulutuse ID:
- A22956316
- Viitenumber:
- 25722
- Värskendus:
- viimati kuupäeval 13.10.2026
Kirjeldus
Weiss
Weiss ShockEvent D/210/a/V1
Type of equipment: Temperature cycling shock test chamber
Testing principle: Stationary test chamber with supply of warm, cold, and ambient air via flaps
Test chamber volume: approx. 210 liters
Usable test chamber width / height according to the installation plan: 700 / 500 mm
Installation dimensions according to the installation plan (W × D × H): approx. 1,480 × 1,670 × 1,967 mm, plus space for attachments
Gbodpfx Acsz Rwk Rskou
Weight: approx. 1,350 kg
Temperature range, warm chamber: +50 to +225 °C
Temperature range, test chamber, warm phase: +50 to +200 °C
Temperature range, test chamber, cold phase: −65 to 0 °C
Temperature range, cold chamber: −70 to 0 °C
Heating rate: 18 K/min, i.e. 18 °C
Cooling rate: 2 K/min, i.e. 2 °C
Temperature deviation over time: ±0.3 to ±0.5 K in the steady state
Temperature homogeneity spatially: ±0.5 to ±1.5 K
Heat compensation, cold phase: max. 6,000 W at −20 °C
Heat compensation, warm phase: 0 W
Maximum load on test chamber floor: 100 kg, evenly distributed
Maximum number of insert baskets: 7
Maximum load per insert basket: 7.5 kg
Maximum total load of the insert baskets: 50 kg
Distance between the insert baskets: 50 mm
Operation: WEBPanel touch display with WEBSeason®
Remote control: via computer, smartphone or tablet
Interfaces: Ethernet, USB and Digital I/O
Power connection: 3/N/PE AC 400 V ±10 %, 50 Hz; actual design according to the nameplate
Other connection options according to the manual: 380 V / 50 Hz or optionally 440 V / 60 Hz
Rated power: 31.9 kW
Rated current: 57 A
On-site protection: 63 A slow-blow fuse
Protection class of the control cabinet and operating panel: IP23
Cooling: water-cooled
Cooling water connections: supply and return, each with 1" internal thread
Cooling water temperature: +12 to +28 °C
Cooling water pressure: 2.5 to 6 bar
Differential pressure of the cooling water circuit: over 2 bar
Cooling water consumption under full load at 18 °C inlet and 10 K heating: 2.9 m³/h
Cooling water consumption under full load at 28 °C inlet and 5 K heating: 5.8 m³/h
Maximum heat dissipation to the cooling water: 33.7 kW
Maximum heat dissipation to the installation room: 1 kW
Compressed air supply: 4 to 10 bar overpressure
Compressed air connection: quick-release coupling DN 7.2
Compressed air temperature: +2 to +50 °C
Condensate drain: hose connection Ø 8 mm
Sound pressure level: approx. 63 dB(A)
Permissible ambient temperature during operation: +10 to +35 °C
Permissible relative humidity at the installation site: maximum 75 %
Refrigerant:
R449A 3.5 kg
R469A 2.5 kg
Shipping or forwarding possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Weiss ShockEvent D/210/a/V1
Type of equipment: Temperature cycling shock test chamber
Testing principle: Stationary test chamber with supply of warm, cold, and ambient air via flaps
Test chamber volume: approx. 210 liters
Usable test chamber width / height according to the installation plan: 700 / 500 mm
Installation dimensions according to the installation plan (W × D × H): approx. 1,480 × 1,670 × 1,967 mm, plus space for attachments
Gbodpfx Acsz Rwk Rskou
Weight: approx. 1,350 kg
Temperature range, warm chamber: +50 to +225 °C
Temperature range, test chamber, warm phase: +50 to +200 °C
Temperature range, test chamber, cold phase: −65 to 0 °C
Temperature range, cold chamber: −70 to 0 °C
Heating rate: 18 K/min, i.e. 18 °C
Cooling rate: 2 K/min, i.e. 2 °C
Temperature deviation over time: ±0.3 to ±0.5 K in the steady state
Temperature homogeneity spatially: ±0.5 to ±1.5 K
Heat compensation, cold phase: max. 6,000 W at −20 °C
Heat compensation, warm phase: 0 W
Maximum load on test chamber floor: 100 kg, evenly distributed
Maximum number of insert baskets: 7
Maximum load per insert basket: 7.5 kg
Maximum total load of the insert baskets: 50 kg
Distance between the insert baskets: 50 mm
Operation: WEBPanel touch display with WEBSeason®
Remote control: via computer, smartphone or tablet
Interfaces: Ethernet, USB and Digital I/O
Power connection: 3/N/PE AC 400 V ±10 %, 50 Hz; actual design according to the nameplate
Other connection options according to the manual: 380 V / 50 Hz or optionally 440 V / 60 Hz
Rated power: 31.9 kW
Rated current: 57 A
On-site protection: 63 A slow-blow fuse
Protection class of the control cabinet and operating panel: IP23
Cooling: water-cooled
Cooling water connections: supply and return, each with 1" internal thread
Cooling water temperature: +12 to +28 °C
Cooling water pressure: 2.5 to 6 bar
Differential pressure of the cooling water circuit: over 2 bar
Cooling water consumption under full load at 18 °C inlet and 10 K heating: 2.9 m³/h
Cooling water consumption under full load at 28 °C inlet and 5 K heating: 5.8 m³/h
Maximum heat dissipation to the cooling water: 33.7 kW
Maximum heat dissipation to the installation room: 1 kW
Compressed air supply: 4 to 10 bar overpressure
Compressed air connection: quick-release coupling DN 7.2
Compressed air temperature: +2 to +50 °C
Condensate drain: hose connection Ø 8 mm
Sound pressure level: approx. 63 dB(A)
Permissible ambient temperature during operation: +10 to +35 °C
Permissible relative humidity at the installation site: maximum 75 %
Refrigerant:
R449A 3.5 kg
R469A 2.5 kg
Shipping or forwarding possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Saada päring
Telefon & Faks
+49 2861 ... kuulutused