TIRA kliimakamber TCC 7120 -75°C / +180°C koos niiskuse funktsioonigaTIRA
Klimakammer
TIRA kliimakamber TCC 7120 -75°C / +180°C koos niiskuse funktsiooniga
TIRA
Klimakammer
Seisund
Kasutatud
Asukoht
Borken 

Põhiandmed
Hind ja asukoht
- Asukoht:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Helistada
Pakkumise üksikasjad
- kuulutuse ID:
- A22242797
- Viitenumber:
- 24604
- Värskendus:
- viimati kuupäeval 15.10.2026
Kirjeldus
TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the test chamber) ±0.1°C ... ±0.3°C
Maximum temperature change rate
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% to ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x W x H) 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf 50 kg
Maximum floor load of the test chamber 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety as a buyer, please note the following information:
Isdezh Htqspfx Af Tjtn
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the test chamber) ±0.1°C ... ±0.3°C
Maximum temperature change rate
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% to ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x W x H) 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf 50 kg
Maximum floor load of the test chamber 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety as a buyer, please note the following information:
Isdezh Htqspfx Af Tjtn
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Saada päring
Telefon & Faks
+49 2861 ... kuulutused
Teie kuulutus on edukalt kustutatud
Ilmnes viga