Kliimakamber -75°C / +180°C koos niiskuse reguleerimisegaTIRA
TCC 7120
Kliimakamber -75°C / +180°C koos niiskuse reguleerimisega
TIRA
TCC 7120
Seisund
Kasutatud
Asukoht
Borken 

Andmed masina kohta
- Masina nimetus:
- Kliimakamber -75°C / +180°C koos niiskuse reguleerimisega
- Tootja:
- TIRA
- Mudel:
- TCC 7120
- Seisund:
- väga hea (kasutatud)
Hind ja asukoht
- Asukoht:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Helistada
Pakkumise üksikasjad
- kuulutuse ID:
- A22242797
- Viitenumber:
- 24604
- Värskendus:
- viimati kuupäeval 01.07.2026
Kirjeldus
TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space): ±0.1°C ... ±0.3°C
Maximum temperature change rate:
Bledpjzh Htqjfx Aafei
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time: ±1% to ±3%
Dew point range during long-term tests: +2 / +94 °C
Dew point range during short-term tests: -20 / +2 °C
External dimensions (L x W x H): 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H): 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your security as a buyer, please note the following:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have by phone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space): ±0.1°C ... ±0.3°C
Maximum temperature change rate:
Bledpjzh Htqjfx Aafei
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time: ±1% to ±3%
Dew point range during long-term tests: +2 / +94 °C
Dew point range during short-term tests: -20 / +2 °C
External dimensions (L x W x H): 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H): 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your security as a buyer, please note the following:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have by phone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.