Temperatuurikalibraator SIKA TP 3M 165 ESIKA
TP3M165E
Temperatuurikalibraator SIKA TP 3M 165 E
SIKA
TP3M165E
EXW fikseeritud hind lisandub käibemaks
5 000 €
Tootmisaasta
2015
Seisund
Kasutatud
Asukoht
Offenburg 

Pildid näitavad
Kuva kaart
Andmed masina kohta
- Masina nimetus:
- Temperatuurikalibraator SIKA TP 3M 165 E
- Tootja:
- SIKA
- Mudel:
- TP3M165E
- Masina number:
- 1509012
- Tootmisaasta:
- 2015
- Seisund:
- väga hea (kasutatud)
- Töövõimekus:
- täielikult töökorras
Hind ja asukoht
EXW fikseeritud hind lisandub käibemaks
5 000 €
- Asukoht:
- Im Drachenacker 7a, 77656 Offenburg, Deutschland

Helistada
Pakkumise üksikasjad
- kuulutuse ID:
- A21432102
- Värskendus:
- viimati kuupäeval 05.03.2026
Kirjeldus
For sale is a used temperature calibrator from the manufacturer Sika based in Kaufungen, Germany (Made in Germany).
The device was only used as a micro bath/oil bath in our calibration laboratory and is no longer needed.
No additional accessories are included; however, these can be purchased from the manufacturer. (Other measuring equipment shown in the pictures is not included in the offer.)
Temperature range: -30°C to 165°C
Manufacturer specifications:
Description:
Whether for on-site use in the workshop, in the measurement and test room, or in the laboratory, SIKA temperature calibrators are utilized anywhere. A wide range of industries with diverse applications are covered.
• Assembly, commissioning
• Manufacturing, production
Dodpjyrb Hhsfx Aa Nsup
• Maintenance, service
• Quality assurance, test equipment monitoring
• Repair
Micro bath function:
When temperature sensors with unusual shapes and sizes need to be tested, using calibration fluids offers advantages. The unit under test is placed directly in the fluid, ensuring a direct heat transfer between calibrator and device without insulating air gaps. The calibration fluid, such as silicone oil, is selected according to the required calibration temperature. The stepless regulation of the magnetic stirrer, combined with the removable sensor basket, ensures thorough mixing of the calibration liquid and creates a large measurement zone. Furthermore, the sensor basket allows undisturbed stirring operation and protects the tank bottom.
Dry block function:
The dry block function is designed to allow simple temperature calibration in laboratory and field applications. Optimal thermal coupling between the block and the device under test is achieved using the correct sleeve. Ideally, the bore in the sleeve should be 0.5 mm larger in diameter than the outside diameter of the sensor. The sleeve enables calibration of almost all straight temperature sensors with different lengths and diameters. The dry block covers the entire temperature range without the need to change the calibration medium. The user does not have to consider viscosities, flash points, or outgassing.
Blackbody function:
For the calibration of IR pyrometers or thermal imaging cameras, a patented infrared calibration sleeve is used. The special surface structure and asymmetric shapes create a “black cavity radiator” with an emissivity factor of 0.9994, preventing the reflection of stray radiation and emitting the desired temperature in an ideal manner. The pyrometer is simply held at the prescribed distance above the measurement opening, allowing the desired measurement spot on the base to be targeted for calibration. Direct mounting of a tripod is possible.
Surface temperature function:
Surface temperature sensors are calibrated using special sleeves that are placed vertically with the required contact force. By switching the calibrator controller to the external reference sensor, the best possible temperature reference point on the sleeve surface is achieved.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
The device was only used as a micro bath/oil bath in our calibration laboratory and is no longer needed.
No additional accessories are included; however, these can be purchased from the manufacturer. (Other measuring equipment shown in the pictures is not included in the offer.)
Temperature range: -30°C to 165°C
Manufacturer specifications:
Description:
Whether for on-site use in the workshop, in the measurement and test room, or in the laboratory, SIKA temperature calibrators are utilized anywhere. A wide range of industries with diverse applications are covered.
• Assembly, commissioning
• Manufacturing, production
Dodpjyrb Hhsfx Aa Nsup
• Maintenance, service
• Quality assurance, test equipment monitoring
• Repair
Micro bath function:
When temperature sensors with unusual shapes and sizes need to be tested, using calibration fluids offers advantages. The unit under test is placed directly in the fluid, ensuring a direct heat transfer between calibrator and device without insulating air gaps. The calibration fluid, such as silicone oil, is selected according to the required calibration temperature. The stepless regulation of the magnetic stirrer, combined with the removable sensor basket, ensures thorough mixing of the calibration liquid and creates a large measurement zone. Furthermore, the sensor basket allows undisturbed stirring operation and protects the tank bottom.
Dry block function:
The dry block function is designed to allow simple temperature calibration in laboratory and field applications. Optimal thermal coupling between the block and the device under test is achieved using the correct sleeve. Ideally, the bore in the sleeve should be 0.5 mm larger in diameter than the outside diameter of the sensor. The sleeve enables calibration of almost all straight temperature sensors with different lengths and diameters. The dry block covers the entire temperature range without the need to change the calibration medium. The user does not have to consider viscosities, flash points, or outgassing.
Blackbody function:
For the calibration of IR pyrometers or thermal imaging cameras, a patented infrared calibration sleeve is used. The special surface structure and asymmetric shapes create a “black cavity radiator” with an emissivity factor of 0.9994, preventing the reflection of stray radiation and emitting the desired temperature in an ideal manner. The pyrometer is simply held at the prescribed distance above the measurement opening, allowing the desired measurement spot on the base to be targeted for calibration. Direct mounting of a tripod is possible.
Surface temperature function:
Surface temperature sensors are calibrated using special sleeves that are placed vertically with the required contact force. By switching the calibrator controller to the external reference sensor, the best possible temperature reference point on the sleeve surface is achieved.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Dokumendid
Pakkuja
Märkus: Registreeru tasuta või logi sisse, et saada kogu teave.
Registreeritud alates: 2023
1 Kuulutus onlines
Saada päring
Telefon & Faks
+49 170 4... kuulutused
Need kuulutused võivad samuti teile huvi pakkuda.
Väike kuulutus
Saksamaa
1 242 km
CNC treipingi
Style650/3000
Style650/3000
Väike kuulutus
Borken
1 369 km
Traadi- ja lindiväänemasin, stants nr 15
Schroeder & BauerWB 32-1
Schroeder & BauerWB 32-1
Väike kuulutus
Tönisvorst
1 426 km
Lekke detektor
Airflow UKLM 1
Airflow UKLM 1
Väike kuulutus
Oława
984 km
Tööriista eelseadistusseade
OCS ALFA -SYSSARA-SET 33 SWift
OCS ALFA -SYSSARA-SET 33 SWift
Väike kuulutus
Wiefelstede
1 205 km
Isikliku maanduse katseseade
WarmbierSafety Pips 7100.181
WarmbierSafety Pips 7100.181
Teie kuulutus on edukalt kustutatud
Ilmnes viga