S/S LAGARDE staatiline autoklaav 4 BLagarde
S/S LAGARDE staatiline autoklaav 4 B
Lagarde
Seisund
Kasutatud
Asukoht
Lorquí 

Pildid näitavad
Kuva kaart
Andmed masina kohta
Hind ja asukoht
- Asukoht:
- Polígono Industrial de Lorquí Parcela 129, 30564 Lorquí, España

Helistada
Pakkumise üksikasjad
- kuulutuse ID:
- A20900242
- Värskendus:
- viimati kuupäeval 09.01.2026
Kirjeldus
Autoclaves are used for the sterilization of packaged products that need to reach high temperatures (+100ºC) for the elimination or inactivation of pathogenic microorganisms.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
Gsdpfex S Ipwjx Adasbg
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
Gsdpfex S Ipwjx Adasbg
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Dokumendid
Pakkuja
Märkus: Registreeru tasuta või logi sisse, et saada kogu teave.
Saada päring
Telefon & Faks
+34 968 6... kuulutused
Teie kuulutus on edukalt kustutatud
Ilmnes viga