GBS Prüfpuls rev3 impulssigeneraator pikaajalisteks isolatsioonitestideks kuni 6 nFGBS Elektronik
rev3 Isolationstests bis 6nF
GBS Prüfpuls rev3 impulssigeneraator pikaajalisteks isolatsioonitestideks kuni 6 nF
GBS Elektronik
rev3 Isolationstests bis 6nF
VB lisandub käibemaks
3 781 €
Seisund
Kasutatud
Asukoht
Borken 

Põhiandmed
Hind ja asukoht
VB lisandub käibemaks
3 781 €
- Asukoht:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Helistada
Pakkumise üksikasjad
- kuulutuse ID:
- A17569468
- Viitenumber:
- 21007
- Värskendus:
- viimati kuupäeval 21.10.2026
Kirjeldus
GBS Prüfpuls rev3 Pulse generator for long-term insulation tests
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Hjdsu Egz Rjpfx Acnew
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
More items - new and used - can be found in our shop!
International shipping costs on request!
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Hjdsu Egz Rjpfx Acnew
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
More items - new and used - can be found in our shop!
International shipping costs on request!
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Pakkuja
Märkus: Registreeru tasuta või logi sisse, et saada kogu teave.
Registreeritud alates: 2008
535 Kuulutused internetis
Saada päring
Telefon & Faks
+49 2862 ... kuulutused
Need kuulutused võivad samuti teile huvi pakkuda.
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Wiefelstede
1 205 km
Pingikruustang 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Teie kuulutus on edukalt kustutatud
Ilmnes viga






















