Fresenius Pilot A2 Syringe Pump
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
The device is used in everyday medical practice for the continuous, precisely controlled administration of highly potent medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for flow rate indication, as well as automatic safety and alarm functions.
Thanks to the already mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic recognition and compatibility with common 20 ml and 50 ml Luer-Lock syringes (presets for, among others, BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for precise flow rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery level.
- Mobility: Integrated battery for bridging during patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Voltage supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety functions: Acoustic and visual alarm systems (e.g., in case of occlusion/pressure, syringe positioning, power failure, or low battery)
Nodpe Af Uxfefx Acnswn
Year of manufacture: 2013
"Everything from one source: We would be happy to offer you suitable bank financing for your project."
You can find more items - new and used - in our shop!
International shipping costs on request!
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
The device is used in everyday medical practice for the continuous, precisely controlled administration of highly potent medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for flow rate indication, as well as automatic safety and alarm functions.
Thanks to the already mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic recognition and compatibility with common 20 ml and 50 ml Luer-Lock syringes (presets for, among others, BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for precise flow rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery level.
- Mobility: Integrated battery for bridging during patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Voltage supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety functions: Acoustic and visual alarm systems (e.g., in case of occlusion/pressure, syringe positioning, power failure, or low battery)
Nodpe Af Uxfefx Acnswn
Year of manufacture: 2013
"Everything from one source: We would be happy to offer you suitable bank financing for your project."
You can find more items - new and used - in our shop!
International shipping costs on request!
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Pakkuja
Märkus: Registreeru tasuta või logi sisse, et saada kogu teave.
Viimati sees: eelmisel nädalal
Registreeritud alates: 2008
536 Kuulutused internetis
Saada päring
Telefon & Faks
+49 2862 ... kuulutused
Need kuulutused võivad samuti teile huvi pakkuda.
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Borken
1 368 km
Fresenius Vial Pilot A2 meditsiiniline infusiooni- ja süstlapump (perfusor), kasutatud
FreseniusPilot A2
FreseniusPilot A2
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Borken
1 368 km
Fresenius Vial Pilot A2 meditsiiniline infusiooni- ja süstlapump Perfusor c
FreseniusPilot A2
FreseniusPilot A2
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Borken
1 368 km
Fresenius Vial Pilot A2 meditsiiniline infusiooni- ja süstlapump, perfuusor
FreseniusPilot A2
FreseniusPilot A2
Teie kuulutus on edukalt kustutatud
Ilmnes viga