Kirjeldus
CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Caodpfxsihb Ams Ahwja
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Caodpfxsihb Ams Ahwja
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Pakkuja
Märkus: Registreeru tasuta või logi sisse, et saada kogu teave.
Registreeritud alates: 2012
Saada päring
Telefon & Faks
+49 2861 ... kuulutused
Need kuulutused võivad samuti teile huvi pakkuda.
väike kuulutus
Hochdorf
1 499 km
Temperatuuri jahutusseade (TCU)
SingleCompact WK3-160-9-50 (IM160F)
SingleCompact WK3-160-9-50 (IM160F)
väike kuulutus
Berlin
1 001 km
Aksiaalne kondensaator
Güntner AGGVH 100.2A/2x3-J(D)
Güntner AGGVH 100.2A/2x3-J(D)
väike kuulutus
Tata
1 298 km
Vedeliku jahuti kondensaator
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
väike kuulutus
Forst
1 498 km
100 m³ puhvritank, 3 baari, isoleeritud
väike kuulutus
Delmenhorst
1 192 km
1000L survepaak Puhvripaak Puhvripaak
10539
10539
väike kuulutus
Schmölln
1 177 km
Külmkamber
Dresdner Kühlanlagenbau
Dresdner Kühlanlagenbau
väike kuulutus
Niedźwiedź
1 051 km
Kaheastmeline kompressor
BitzerS6G-25.2Y (x4)
BitzerS6G-25.2Y (x4)
väike kuulutus
Saksamaa
1 242 km
Edgebander
HOLZHERARCUS 1334 FV2
HOLZHERARCUS 1334 FV2
väike kuulutus
Borken
1 367 km
Kliimakatsekamber niiskusega 1000 liitrit
CTSC-40/1000 -40°C bis +180°C
CTSC-40/1000 -40°C bis +180°C
väike kuulutus
Nattheim
1 464 km
Püstine saag
Holz-Her1255
Holz-Her1255
Teie kuulutus on edukalt kustutatud
Ilmnes viga