Temperatuuri testkapp, plahvatuskindel
CTS T-30/950 Ex/I

Tootmisaasta
2011
Seisund
Kasutatud
Asukoht
Borken Saksamaa
Temperatuuri testkapp, plahvatuskindel CTS T-30/950 Ex/I
Temperatuuri testkapp, plahvatuskindel CTS T-30/950 Ex/I
Temperatuuri testkapp, plahvatuskindel CTS T-30/950 Ex/I
Temperatuuri testkapp, plahvatuskindel CTS T-30/950 Ex/I
Temperatuuri testkapp, plahvatuskindel CTS T-30/950 Ex/I
Temperatuuri testkapp, plahvatuskindel CTS T-30/950 Ex/I
Temperatuuri testkapp, plahvatuskindel CTS T-30/950 Ex/I
Temperatuuri testkapp, plahvatuskindel CTS T-30/950 Ex/I
more Images
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I

Andmed masina kohta

Masina nimetus:
Temperatuuri testkapp, plahvatuskindel
Tootja:
CTS
Mudel:
T-30/950 Ex/I
Tootmisaasta:
2011
Seisund:
väga hea (kasutatud)

Hind ja asukoht

Asukoht:
Einsteinstraße 8a, 46325 Borken, Deutschland Saksamaa
Helistada

Pakkumise üksikasjad

kuulutuse ID:
A22147762
Viitenumber:
23117
Värskendus:
viimati kuupäeval 18.06.2026

Kirjeldus

CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:

Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Nodpezd Rzwjfx Anqecu
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:

Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.

Pakkuja

Registreeritud alates: 2012

591 Kuulutused internetis

Trustseal icon
Helistada

Saada päring

Maaus 
Saksamaa
Austria
Šveits
Ameerika Ühendriigid
Suurbritannia
Prantsusmaa
Belgia
Hispaania
Mehhiko
Itaalia
Holland
Poola
Vene Föderatsioon
Valgevene (Valgevene Vabariik)
Ukraina
Eesti
Türgi
Uus-Meremaa
Iirimaa
Tšehhi Vabariik
Taani
Soome
Rootsi
Norra
Luksemburg
Kreeka
Leedu
Läti
Island
Portugal
Brasiilia
Venezuela
Argentiina
Ungari
Slovakkia
Rumeenia
Moldova
Sloveenia
Serbia
Montenegro
Albaania
Horvaatia
Bulgaaria
Põhja-Makedoonia
Bosnia ja Hertsegoviina
Iisrael
Egiptus
Maroko
India
Indoneesia
Lõuna-Korea
Jaapan
Tai
Malaisia
Vietnam
Hiina, Rahvavabariik
Taiwan
Iraan
Bangladesh
Märkus: Teie päring edastatakse kõikidele selle masinakategooria müüjatele. See võimaldab teil saada väga palju pakkumisi.
Päringut ei õnnestunud saata. Palun proovige hiljem uuesti.

Telefon & Faks

+49 2861 ... kuulutused