Kliimakapp niiskuse reguleerimisegaBinder
MKF 115 E3.1 -40°C bis 180°C
Kliimakapp niiskuse reguleerimisega
Binder
MKF 115 E3.1 -40°C bis 180°C
Seisund
Kasutatud
Asukoht
Borken 

Pildid näitavad
Kuva kaart
Andmed masina kohta
Hind ja asukoht
- Asukoht:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Helistada
Pakkumise üksikasjad
- kuulutuse ID:
- A20959057
- Viitenumber:
- 24976
- Värskendus:
- viimati kuupäeval 15.01.2026
Kirjeldus
Binder
Model MKF 115 E3.1
Binder Climatic Test Chamber Model MKF 115 E3.1
Temperature range: -40 °C to +180 °C
Humidity range: 10 % RH to 98 % RH
Integrated 20 L water reservoir
4 potential-free relay contacts
APT.line™ preheating chamber technology
Programmable condensation protection for samples
Heated viewing window with LED chamber illumination
Humidity control with capacitive humidity sensor and steam humidification
BINDER Multi Management Software APT-COM™ Basic Edition
Fault diagnosis system with visual and audible alarms
Intuitive touchscreen controller with time-segment and real-time programming
Internal data logger, measurement data exportable in open format via USB
Godpfx Adsx Ux Ivjaott
50 mm access port with silicone stopper, left side
Class 2 temperature safety limiter (DIN 12880) with visual alarm
4 casters (2 with locking brakes)
Computer interface: Ethernet
230 V outlet on right side control panel
Adjustable ramp function
Integrated strip chart recorder
Real-time clock
Door heating
Alarm notification on low water level in the fresh water tank
2 stainless steel shelves
Hose burst protection, incl. water supply and drain up to 1m height
Interior chamber made of stainless steel
Cooling by compression refrigeration unit
TECHNICAL DATA:
Cabinet dimensions:
Width 1000 mm Height 1725 mm incl. feet/castors Depth 865 mm incl. lugs &/connections
Interior dimensions:
Width 600 mm Height 480 mm Depth 400 mm
Volume:
Chamber volume 115 liters
Net device weight (empty) 280 kg
Max. total load 60 kg
Max. load per shelf 30 kg
Performance data Temperature:
Temperature range -40...180°C
Temporal temperature deviation 0.1...0.6 ± K
Spatial temperature deviation 0.1...1.3 ± K
Average heat-up rate according to IEC 60068-3-5: 5.5 K/min
Average cool-down rate according to IEC 60068-3-5: 4.5 K/min
Max. heat compensation 2500 W
Climate performance data:
Temperature range 10...95°C
Humidity range 10...98 % RH
Temporal temperature deviation depending on setpoint 0.1...1.3 ± K
Max. heat compensation 400 W
Electrical data:
Rated voltage 400V 3N~ ±10% 50Hz
Rated power 4.5 kW 7.5 A
Energy consumption at 25°C / 60% RH 1.25 kW
Fittings:
Number of shelves 4/4 (std./max.)
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors!)
If you have further questions, we would be happy to answer them by phone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Model MKF 115 E3.1
Binder Climatic Test Chamber Model MKF 115 E3.1
Temperature range: -40 °C to +180 °C
Humidity range: 10 % RH to 98 % RH
Integrated 20 L water reservoir
4 potential-free relay contacts
APT.line™ preheating chamber technology
Programmable condensation protection for samples
Heated viewing window with LED chamber illumination
Humidity control with capacitive humidity sensor and steam humidification
BINDER Multi Management Software APT-COM™ Basic Edition
Fault diagnosis system with visual and audible alarms
Intuitive touchscreen controller with time-segment and real-time programming
Internal data logger, measurement data exportable in open format via USB
Godpfx Adsx Ux Ivjaott
50 mm access port with silicone stopper, left side
Class 2 temperature safety limiter (DIN 12880) with visual alarm
4 casters (2 with locking brakes)
Computer interface: Ethernet
230 V outlet on right side control panel
Adjustable ramp function
Integrated strip chart recorder
Real-time clock
Door heating
Alarm notification on low water level in the fresh water tank
2 stainless steel shelves
Hose burst protection, incl. water supply and drain up to 1m height
Interior chamber made of stainless steel
Cooling by compression refrigeration unit
TECHNICAL DATA:
Cabinet dimensions:
Width 1000 mm Height 1725 mm incl. feet/castors Depth 865 mm incl. lugs &/connections
Interior dimensions:
Width 600 mm Height 480 mm Depth 400 mm
Volume:
Chamber volume 115 liters
Net device weight (empty) 280 kg
Max. total load 60 kg
Max. load per shelf 30 kg
Performance data Temperature:
Temperature range -40...180°C
Temporal temperature deviation 0.1...0.6 ± K
Spatial temperature deviation 0.1...1.3 ± K
Average heat-up rate according to IEC 60068-3-5: 5.5 K/min
Average cool-down rate according to IEC 60068-3-5: 4.5 K/min
Max. heat compensation 2500 W
Climate performance data:
Temperature range 10...95°C
Humidity range 10...98 % RH
Temporal temperature deviation depending on setpoint 0.1...1.3 ± K
Max. heat compensation 400 W
Electrical data:
Rated voltage 400V 3N~ ±10% 50Hz
Rated power 4.5 kW 7.5 A
Energy consumption at 25°C / 60% RH 1.25 kW
Fittings:
Number of shelves 4/4 (std./max.)
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors!)
If you have further questions, we would be happy to answer them by phone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Pakkuja
Märkus: Registreeru tasuta või logi sisse, et saada kogu teave.
Saada päring
Telefon & Faks
+49 2861 ... kuulutused
Teie kuulutus on edukalt kustutatud
Ilmnes viga