BAC S15E 1018-10 LE avatud aurustumisjahutustorn, jahutustorn, tagasijahuti, jahutusseadeBAC
S15E 1018-10 LE
BAC S15E 1018-10 LE avatud aurustumisjahutustorn, jahutustorn, tagasijahuti, jahutusseade
BAC
S15E 1018-10 LE
VB lisandub käibemaks
26 800 €
Seisund
Kasutatud
Asukoht
Borken 

Põhiandmed
- Masina nimetus:
- BAC S15E 1018-10 LE avatud aurustumisjahutustorn, jahutustorn, tagasijahuti, jahutusseade
- Tootja:
- BAC
- Mudel:
- S15E 1018-10 LE
- Seisund:
- kasutatud
Hind ja asukoht
VB lisandub käibemaks
26 800 €
- Asukoht:
- 46325 Borken, Deutschland

Helistada
Pakkumise üksikasjad
- kuulutuse ID:
- A21340202
- Viitenumber:
- 60821
- Värskendus:
- viimati kuupäeval 21.10.2026
Kirjeldus
BAC S1500E Cooling Tower
The BAC S15E 1018-10-LE is a high-performance, open-circuit cooling tower from the S1500E series manufactured by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are priorities.
Lhjdeynkbmopfx Adcsn
Technology
Patented BACross III fill media system, which allows for easy inspection of the fill to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance access: A large, inward-swinging access door and internal maintenance platforms allow technicians to conveniently perform inspections while standing inside the unit.
Hygiene control: The design minimizes standing water and protects against sunlight through special air inlet elements, reducing algae growth.
Flexibility: The single-sided air intake allows the cooling tower to be installed even in confined spaces or directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial cooling: Used in factories for process cooling.
HVAC: Used in large building complexes as part of a central chiller system.
Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW cooling capacity, as the actual performance depends entirely on the thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model is in the range of approximately 1,200 kW to 2,100 kW.
Why does the cooling capacity vary?
Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate, and the higher the cooling capacity.
Water temperatures: The performance changes significantly depending on the warm water inlet temperature (e.g., 35 °C) and the cold water outlet temperature (e.g., 29 °C).
Air volume flow: According to BAC's technical data, the S15E 1018-10 LE model actively moves 60.0 m³/s of air through three installed 11.0 kW fan motors.
If this air volume is reduced by a frequency inverter (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This is the most important thermodynamic limit. It describes the difference between the desired cold water temperature and the physically determined wet-bulb temperature. The closer the cold water is cooled to the wet-bulb temperature (smaller approach), the less kW of power the tower can provide.
Technical Data:
Fan and Air Data
- Air volume flow: 60.0 m³/s (generated in suction operation)
- Fan motors: 3x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow: 198 l/s
Hydraulic Connections
- Water inlet: 1x DN 250 (nominal size ND 250 mm)
- Water outlet: 1x DN 300 (nominal size ND 300 mm)
- Make-up water connection: 1x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Dimensions and Weights
- Operating weight: 11,446 kg (including water fill up to overflow)
- Shipping weight: 5,350 kg (empty weight)
- Heaviest single part: 3,114 kg (for installation)
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
The BAC S15E 1018-10-LE is a high-performance, open-circuit cooling tower from the S1500E series manufactured by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are priorities.
Lhjdeynkbmopfx Adcsn
Technology
Patented BACross III fill media system, which allows for easy inspection of the fill to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance access: A large, inward-swinging access door and internal maintenance platforms allow technicians to conveniently perform inspections while standing inside the unit.
Hygiene control: The design minimizes standing water and protects against sunlight through special air inlet elements, reducing algae growth.
Flexibility: The single-sided air intake allows the cooling tower to be installed even in confined spaces or directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial cooling: Used in factories for process cooling.
HVAC: Used in large building complexes as part of a central chiller system.
Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW cooling capacity, as the actual performance depends entirely on the thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model is in the range of approximately 1,200 kW to 2,100 kW.
Why does the cooling capacity vary?
Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate, and the higher the cooling capacity.
Water temperatures: The performance changes significantly depending on the warm water inlet temperature (e.g., 35 °C) and the cold water outlet temperature (e.g., 29 °C).
Air volume flow: According to BAC's technical data, the S15E 1018-10 LE model actively moves 60.0 m³/s of air through three installed 11.0 kW fan motors.
If this air volume is reduced by a frequency inverter (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This is the most important thermodynamic limit. It describes the difference between the desired cold water temperature and the physically determined wet-bulb temperature. The closer the cold water is cooled to the wet-bulb temperature (smaller approach), the less kW of power the tower can provide.
Technical Data:
Fan and Air Data
- Air volume flow: 60.0 m³/s (generated in suction operation)
- Fan motors: 3x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow: 198 l/s
Hydraulic Connections
- Water inlet: 1x DN 250 (nominal size ND 250 mm)
- Water outlet: 1x DN 300 (nominal size ND 300 mm)
- Make-up water connection: 1x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Dimensions and Weights
- Operating weight: 11,446 kg (including water fill up to overflow)
- Shipping weight: 5,350 kg (empty weight)
- Heaviest single part: 3,114 kg (for installation)
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Pakkuja
Märkus: Registreeru tasuta või logi sisse, et saada kogu teave.
Viimati sees: eile
Registreeritud alates: 2008
532 Kuulutused internetis
Saada päring
Telefon & Faks
+49 2862 ... kuulutused
Need kuulutused võivad samuti teile huvi pakkuda.
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Łęczna
823 km
Jahuti / Soojuspump
New Chiller / Heat pumpBlue Box 16/18 kW | With warranty
New Chiller / Heat pumpBlue Box 16/18 kW | With warranty
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Dinkelscherben
1 485 km
Konveierilint Kaldkonveierilint Konveierisüsteem
die magnetprofis2021100803
die magnetprofis2021100803
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Niedźwiedź
1 051 km
Õhujahuti
GüntnerS-GGN 066C/27
GüntnerS-GGN 066C/27
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Remseck am Neckar
1 493 km
Tööstuslik külmutuskompressorjaam Bitzeriga
Bitzer Verbundanlage6J-22.2Y-40P/ 4H-15.2Y-40P
Bitzer Verbundanlage6J-22.2Y-40P/ 4H-15.2Y-40P
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Hillegom
1 461 km
Jahutusmasin
YorkYLCS1110HA 50Y A
YorkYLCS1110HA 50Y A
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Niedźwiedź
1 051 km
Külmutuskompressor
DWM CopelandD6DH3-3500-AWM/D
DWM CopelandD6DH3-3500-AWM/D
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Rumeenia
1 513 km
Engel DUO 3550/400 pico
EngelDUO 3550/400 pico
EngelDUO 3550/400 pico
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Hillegom
1 461 km
Kuivjahuti
CaberoGCHSD089MB/X7S-40 Y V
CaberoGCHSD089MB/X7S-40 Y V
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Niedźwiedź
1 051 km
Kondensaator
GüntnerGVH 090.2A/2x5-N(D)
GüntnerGVH 090.2A/2x5-N(D)
Edukas
Teie sõnum on saadetud.
Väike kuulutus
Hillegom
1 461 km
Jahutustorn
EvapcoATW 36-4M
EvapcoATW 36-4M
Teie kuulutus on edukalt kustutatud
Ilmnes viga