ACS Angelantoni 2× Discovery DM 1200 CES esitulede kliimakatse süsteem koos Huber Unichilleri jahutuACS Angelantoni
Discovery DM 1200 CES
ACS Angelantoni 2× Discovery DM 1200 CES esitulede kliimakatse süsteem koos Huber Unichilleri jahutu
ACS Angelantoni
Discovery DM 1200 CES
Seisund
Kasutatud
Asukoht
Borken 

Põhiandmed
- Masina nimetus:
- ACS Angelantoni 2× Discovery DM 1200 CES esitulede kliimakatse süsteem koos Huber Unichilleri jahutu
- Tootja:
- ACS Angelantoni
- Mudel:
- Discovery DM 1200 CES
- Seisund:
- kasutatud
Hind ja asukoht
- Asukoht:
- Borken, Saksamaa

Helistada
Pakkumise üksikasjad
- kuulutuse ID:
- A23371339
- Viitenumber:
- 25844
- Värskendus:
- viimati kuupäeval 23.11.2026
Kirjeldus
ACS Angelantoni Test Technologies
Discovery 2 x DM 1200 C ES
Laods Aliwnopfx Agkoi
Headlight climate testing system with coupling chamber
Year of manufacture: 2019 / approx. 5,000 kg
2 test chambers with Huber Unichiller 040T
For sale is a used, coupled climate and temperature testing system for testing vehicle headlights.
System configuration / scope of supply:
2 x ACS Discovery climate test chamber
1 x central coupling / test chamber
1 x associated electrical control cabinet
1 x Huber Unichiller 040T
Connection hoses as shown in the pictures
Technical data – ACS:
Manufacturer: ACS / Angelantoni Test Technologies
Model series: Discovery
Type: 2 x DM 1200 C ES + BOX
Year of manufacture: 2019
Weight: approx. 5,000 kg
Main nameplate: 4,575 kg
Additional nameplate: 1,170 kg (not added)
Usable volume according to drawing: approx. 1 m³ per specified test / coupling unit
Temperature and climate data:
Temperature according to nameplate: -75 to +180 °C
Combined, outside: -40 to +130 °C
Combined, engine side: -40 to +180 °C
Separate operation: -70 to +180 °C
Relative humidity according to nameplate: 10-98 %
Dew point range according to drawing: +4 to +80 °C
Supply / cooling technology:
Total system according to drawing: 400 V / 50 Hz
Installed power according to drawing: 54 kW
Average power: approx. 30 kW
Workshop data: 41 A / approx. 20.86 kW
Max. cooling water consumption: 6 m³/h
ACS refrigerant: R452A / 5.00 kg and R23 / 1.10 kg
Electrical equipment (EB_BOX):
400 V / 3 Ph + N + PE / 50 Hz
Full load current: 9 A / Power: 4 kW
Protection class: IP54 / Tolerance: 10 %
Short-circuit current: 15 kA
Standard: IEC/EN 60204-1
Data applies to EB_BOX.
Huber Unichiller 040T:
Temperature range: -10 to +40 °C
Connection: 400 V / 3~ / 50 Hz
Max. current consumption: 5.0 A
Refrigerant: R507A / 2.20 kg
Dimensions according to system layout:
Width closed: approx. 5,200 mm
Width open: up to approx. 8,400 mm
Max. height: approx. 2,460 mm
Condition / workshop inspection:
Used
Heating rate measured: 7.64 K/min
Cooling rate measured: 5.78 K/min
24 V power supply replaced.
Electrical system, fan and R23 refrigerant circuit serviced.
Collection / shipping possible by arrangement.
Subject to changes, errors and prior sale.
We will gladly answer any questions by telephone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Discovery 2 x DM 1200 C ES
Laods Aliwnopfx Agkoi
Headlight climate testing system with coupling chamber
Year of manufacture: 2019 / approx. 5,000 kg
2 test chambers with Huber Unichiller 040T
For sale is a used, coupled climate and temperature testing system for testing vehicle headlights.
System configuration / scope of supply:
2 x ACS Discovery climate test chamber
1 x central coupling / test chamber
1 x associated electrical control cabinet
1 x Huber Unichiller 040T
Connection hoses as shown in the pictures
Technical data – ACS:
Manufacturer: ACS / Angelantoni Test Technologies
Model series: Discovery
Type: 2 x DM 1200 C ES + BOX
Year of manufacture: 2019
Weight: approx. 5,000 kg
Main nameplate: 4,575 kg
Additional nameplate: 1,170 kg (not added)
Usable volume according to drawing: approx. 1 m³ per specified test / coupling unit
Temperature and climate data:
Temperature according to nameplate: -75 to +180 °C
Combined, outside: -40 to +130 °C
Combined, engine side: -40 to +180 °C
Separate operation: -70 to +180 °C
Relative humidity according to nameplate: 10-98 %
Dew point range according to drawing: +4 to +80 °C
Supply / cooling technology:
Total system according to drawing: 400 V / 50 Hz
Installed power according to drawing: 54 kW
Average power: approx. 30 kW
Workshop data: 41 A / approx. 20.86 kW
Max. cooling water consumption: 6 m³/h
ACS refrigerant: R452A / 5.00 kg and R23 / 1.10 kg
Electrical equipment (EB_BOX):
400 V / 3 Ph + N + PE / 50 Hz
Full load current: 9 A / Power: 4 kW
Protection class: IP54 / Tolerance: 10 %
Short-circuit current: 15 kA
Standard: IEC/EN 60204-1
Data applies to EB_BOX.
Huber Unichiller 040T:
Temperature range: -10 to +40 °C
Connection: 400 V / 3~ / 50 Hz
Max. current consumption: 5.0 A
Refrigerant: R507A / 2.20 kg
Dimensions according to system layout:
Width closed: approx. 5,200 mm
Width open: up to approx. 8,400 mm
Max. height: approx. 2,460 mm
Condition / workshop inspection:
Used
Heating rate measured: 7.64 K/min
Cooling rate measured: 5.78 K/min
24 V power supply replaced.
Electrical system, fan and R23 refrigerant circuit serviced.
Collection / shipping possible by arrangement.
Subject to changes, errors and prior sale.
We will gladly answer any questions by telephone.
Kuulutus tõlgiti automaatselt. Tõlkevigu võib esineda.
Saada päring
Telefon & Faks
+49 2861 ... kuulutused
Teie kuulutus on edukalt kustutatud
Ilmnes viga